- Port G1/4, G3/8, G1/2, G3/4
- Flow rate 2600 ... 6450 l/min
The duration of the pressure build-up is adjusted with the aid of the enclosed restrictor to the valve cap. The output pressure p2 rises slowly in accordance with the restrictor setting. Only the air flow of the restrictor is available when the solenoid valve is not activated. The head office is only opened by activating the solenoid valve. When the solenoid valve is switched off, the main seat is closed and only the airflow from the flow control valve is available. The solenoid valve must remain on to vent a system because it increases the flow rate from 2 and 1 and reduces the discharge time.
| Function |
Solenoid actuated soft-start valves |
| Connection size/pneumatic connection |
Female wire G1/4 Female wire G3/8 Female wire G1/2 |
| Grid size |
40 mm. 62 mm. |
| Supply voltage |
10V24 supply voltage 24 V DC V110 supply voltage 110 V AC V230 supply voltage 230 V AC |
| Protection class |
IP65 |
| Pressure (bar) |
V24/V110/V230, 4 ...18 10V24/10V24P, 4 ... 10 |
| Medium |
Compressed air according to ISO 85731:2010 [7:4:4] Inert gases |
| Temperature medium (°C) |
-10 ... +60 |
| Corossion resistance class CRC |
2 |
| UL certificate |
cULus recognized (OL) |
| ATEX EU certificate |
EX2, II 3G Ex nA IIC T4 X Gc II 3D Ex tc IIIC T105°C X Dc IP65 |
| Housing |
Cast aluminum |